TANK and TANKLESS HOT WATER CIRCULATOR
EASY 1 - 2 - 3 INSTALL
(Connect sinks HW hoses to E + F and CW hoses to G + H)
We identified the industries need for greener-efficient hot water circulators with install flexibility and control customization capable of satisfying even complex lifestyles. Placing efficiency and comfort first, and foremost combined with over 20 years experience engineering hot water circulators, we achieved our goals. In addition to providing consumers with twice the convenience of other hot water circulators our proprietary controller offers "on-the-fly" comfort temperature optimization. Consumers wanting hotter hot water instantly out their taps simply turn the temperature dial clockwise or counter clockwise to lower the temperature. After only a few adjustments, homeowners will have optimized their hot water system's comfort and readiness. Redytemp homeowners benefit from an optimized hot water lifestyle with unmatched comfort, convenience and water savings.
Engineering Tactic / Benefit
Digital Timer - up to 20 on/off events per day - built-in battery saves program in case of power outage - lifestyle convenience
Solenoid Valve - "M" eliminates costly hot water line siphoning - save energy - extend life of water heater - increase comfort
Isolation Valves - "J + I" meet U.S. WaterSense standards / requirements
Limitless Control - on-demand, timer, wireless, occupancy, etc. - maximum convenience - easy integration
RJ11 Phone Jack - "C" easy multi-pushbutton integration - convenient activation from any location
Flexible Installation - Install pump at sink or water heater (read below)
Detachable Control Box - lollipop cutouts and existing quick connects on wires allow for easy relocation to wall or control room, if desired
Detachable Power Cord - "K" main power input - convenient install without having to cut wires
Adjustable Temperature Control - "D" owner selectable comfort temp - industry record comfort and owner optimized readiness and water savings
Temperature Based Cyclic-Pumping - minimize pump operations - longer lifecycle / retained cold water comfort
On-Demand / Single-Cycle Override - anytime hot water convenience - meet LEED qualifications - maximize savings
Re-locating "water contacting" Temperature Probe - "L" accurate temperature sensing - accurate comfort, optimum water savings


All systems include a Digital Timer /
20
Events
(built-in 30 day backup battery; eliminates standby
energy consumption as well as time corrections / reprogramming after a power outage)
TL4000's Pump Data TL-Series Install / User Guide TL5000's Pump Data
A - CONTROL ENABLER SOCKET (3-Prong Wall Socket) accepts 2 and 3-prong control devices for unlimited control customization.
B - CONTROL ENABLER PLUG (2-Prong Plug) plugs into ANY control device plugged into (A).
If (B) directly to (A) 24 hr cyclic operation, leave unplugged for
on-demand only.
C - ON-DEMAND /
SINGLE-CYCLE RJ11 PHONE JACK.
ANYTIME single-cycle operation
/ scheduled-off overrides, using 1 or more doorbell buttons wired to phone cords
D - TEMPERATURE ADJUSTMENT DIAL optimizes comfort and savings. Range 40°F to 118°F non-limiting
E, F - HOT WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing HW hose and connect
G, H - COLD WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing CW hose and connect
I, J - PUMP ISOLATION SHUT-OFF VALVES Fulfills US WaterSense requirements, convenient pump access and a means to manipulate flow rate
K - MAIN POWER CORD DETACHABLE PLUG-IN Provides power to system.
L - STAINLESS STEEL TEMPERATURE PROBE For "accurate" water contacting temperature sensing for 0.5F deg. adjustment accuracy
M - SILENT ACTION "NORMALLY CLOSED" HW SOLENOID VALVE Prevents HWL siphoning into CWL during CW use. Opens only during active pumping cycle.
DISCOVER RedyTemp®'s USER FRIENDLY CONTROL / ACTIVATION and WIRELESS OPTIONS
HEAD PRESSURE is a pump's ability to move a 1" column of water vertically upwards in a pipe. This being said a TL4000 system would be inadequate in pushing water up to a third floor since it's rated to 16' of head. The TL5000 system would be the better fit.
OPEN LOOP SYSTEM / MODEL DESIGNATOR "N"
COLD LINE USED AS RETURN
Homes with NO DEDICATED hot water return line OPEN-LOOP systems use Cold Water line as return line
TL4000N Small - Med size home Flow 1-14 gpm / 16' head
TL5000N Large size home Flow 1-28 gpm / 30' head
INSTALL TYPE LOCATION
COMMON Pump UNDER SINK connect as follows:
E and F - hot supply and hot faucet (interchangeable / either one)
H and G - cold supply or cold faucet (interchangeable / either one)
ALTERNATE Pump AT WATER HEATER or ON HW LINE REQUIRES ASSEMBLING (SWING CHECK VALVE, TEMP PROBE and SOLENOID)
Requires running 5 wires (2 = temp probe, 3 = solenoid 18 AWG) from control box to by-pass assembly connect wires to temperature probe and solenoid valve wires.
Using appropriate fittings In series connect (1) check valve, temperature probe and solenoid valve, install between hot and cold pipes anywhere near end of line.

The above illustrates that the pump can be placed most anywhere on the hot water line. Beneficial for homes having easy access to plumbing lines in a basement, crawlspace, attic, etc. Placing the by-pass valve assembly near the last hot water load on the loop ensures all loads on the loop are covered. This configuration is often a better choice for pedestal sinks or when space limits prevent a under sink installation.
CLOSED LOOP SYSTEM / MODEL DESIGNATOR "D"
DEDICATED HOT WATER LINE (EXISTING HOT WATER LOOP)
Homes with DEDICATED hot water return line CLOSED-LOOP systems use Hot Water Loop to return water back to water heater
TL4000D Sm - Med size home Flow 1-14 gpm / 16' head
TL5000D Large size home Flow 1-28 gpm / 30' head
INSTALL TYPE LOCATION
COMMON Pump AT WATER HEATER drain spout (helps prevent sediment buildup at bottom of water heater)
Rotate pump head to achieve desired direction of flow into water heaters drain spout (specify direction when placing order we'll do it for you, to save you time)
Connect flanges and temperature probe. (Unless relocating to last load on loop. RECOMMENDED for efficiency) to hot water loop
ALTERNATE Pump ELSEWHERE ON LOOP (for efficiency install probe just after last hot water load)

EFFICIENCY-BASED ENGINEERING
Until now, closed-loop hot water circulation systems typically had a pump and thermostat installed at the water heater on the end of the hot water loop. Often the last load on the loop is a good distance away from the water heater where the pump and thermostat are installed. In these situations, energy is wasted by both pump and water heater delivering hot water beyond the last hot water load. RedyTemp®'s unique design offers significant savings by strategically locating the stainless steel water contacting temperature probe at or near the last hot water load on the loop while still installing the pump at the water heater, or any other, preferred location on the loop. Thereby, minimizing demand placed on the water heater, reducing pump cycle runtimes and extending the lifecycle of the system. Unlike other systems which limit the owner in regards to installation, comfort temperature, activation method, convenience and the ability to reduce their carbon foot print. RedyTemp®'s control features offer homeowner's the ability to optimize their system in a way that best fits their hot water lifestyle expectations. Whatever the preference, be it hot water on-demand, scheduled, a combination of both or even continuous, RedyTemp® delivers the essentials required to optimize efficiency and one's lifestyle.
SAVE MORE $$$ USING "PAY-BY-CHECK" FAX-READY ORDER FORM
click link to see DISCOUNT order form & "PAY-BY-CHECK" prices
WE ALSO OFFER MADE-TO-ORDER SYSTEMS WITH YOUR PREFERRED FITTINGS / CONNECTIONS
Up to 2 story home and distance to water heater < 125'
TL4000D $435.00
Dedicated return line (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,
Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty
TL4000N $489.00 No Dedicated return line / Cold line as return
(Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,
Temperature probe, Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty
Up to 3 story home and distance to water heater < 300'
TL5000D $585.00 Dedicated return line (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011
Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,
Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty
TL5000N $639.00 No Dedicated return line / Cold line as return (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011
Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,
Temperature probe, Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty