TANK and TANKLESS HOT WATER CIRCULATOR
EASY 1 - 2 - 3 INSTALL
(Connect sinks HW hoses to E + F and CW hoses to G + H)
Today's, hot water circulators often fall short, in one way or another of consumer expectations. We identified the industries need for a system that would satisfy a range of unique lifestyles, comfort preferences, control options and conveniences consumers expect of today's appliances. By placing comfort and efficiency as the primary focus combined with over 20 years experience in designing, testing and manufacturing of hot water circulators for commercial and residential applications, we achieved our goals. RedyTemp®'s proprietary controller offers "on-the-fly" hot water comfort optimization and temperature control while also providing the consumer with twice the convenience of any hot water circulators to ever hit the market. Consumers wanting hotter hot water instantly out their tap need only turn the temperature dial clockwise or counter clockwise to lower the temperature and without having to first locate a screwdriver, flashlight or reference materials. After only a few adjustments a homeowner will have optimized there hot water systems readiness without the frustrations caused when cold water comfort is sacrificed to hot water siphoning inefficiencies. Resulting in a lifestyle of comfort, convenience and water savings unmatched to this day.
Engineering Tactic / Benefit
Digital Timer - up to 20 on/off events per day - built-in battery saves program in case of power outage - lifestyle convenience
Solenoid Valve - "M" eliminates costly hot water line siphoning - save energy - extend life of water heater - increase comfort
Isolation Valves - "J + I" meet U.S. WaterSense standards / requirements
Limitless Control - on-demand, timer, wireless, occupancy, etc. - maximum convenience - easy integration
RJ11 Phone Jack - "C" easy multi-pushbutton integration - convenient activation from any location
Flexible Installation - Install pump at sink or water heater (read below)
Detachable Control Box - lollipop cutouts and existing quick connects on wires allow for easy relocation to wall or control room, if desired
Detachable Power Cord - "K" main power input - convenient install without having to cut wires
Adjustable Temperature Control - "D" owner selectable comfort temp - industry record comfort and owner optimized readiness and water savings
Temperature Based Cyclic-Pumping - minimize pump operations - longer lifecycle / retained cold water comfort
On-Demand / Single-Cycle Override - anytime hot water convenience - meet LEED qualifications - maximize savings
Re-locating "water contacting" Temperature Probe - "L" accurate temperature sensing - accurate comfort, optimum water savings


All systems include Digital Timer /
20
Events
(built-in backup battery; no reprogramming power outages)
TL4000's Pump Data TL-Series Install / User Guide TL5000's Pump Data
A - CONTROL SOCKET (3-Prong Wall Socket) accepts 2 and 3-prong control devices.
B - CONTROL ENABLER PLUG (2-Prong Plug) plugs into control device plugged into (A).
If (B) directly to (A) 24 hr cyclic operation, leave unplugged for
on-demand only.
C - ON-DEMAND /
SINGLE-CYCLE RJ11 PHONE JACK.
ANYTIME single cycle operation
/ override .
D - TEMPERATURE ADJUSTMENT DIAL Temperature control optimizes comfort and savings. Range 40°F to 118°F
E, F - HOT WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing HW hose and connect
G, H - COLD WATER SUPPLY / FAUCET 1/2" CONNECTION Interchangeable. Detach "faucet end" of existing CW hose and connect
I, J - ISOLATION SHUT-OFF VALVES Fulfill US WaterSense requirements, convenient pump access and manipulate flow rate, if desired.
K - MAIN POWER DETACHABLE CORD PLUG-IN Provides power to system.
L - STAINLESS STEEL TEMPERATURE PROBE For "accurate" water contacting temperature sensing.
M - SOLENOID VALVE "NORMALLY CLOSED" Prevents ANY HWL siphoning into CWL during CW use. Opens ONLY during an active pumping cycle.
Up to 2 story home and distance to water heater < 125'
TL4000D $435.00
Dedicated return line (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008TL5000D $585.00 Dedicated return line (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011
Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,
Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty
TL4000N $489.00 No Dedicated return line / Cold line as return
(Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008TL5000N $639.00 No Dedicated return line / Cold line as return (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011
Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,
Temperature probe, Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty
Up to 3 story home and distance to water heater < 300'
Optimizer Control Box, 1/2" male connections, Built-in check valve, 2 isolation valves, Temperature probe,
Power cord, 20 event Timer, Install / Users Guide, 2 yr warranty
Optimizer Control Box, 1/2" male connections, Built-in check valve, Anti-siphon solenoid, 2 isolation valves,
Temperature probe, Power cord, 2 Flex lines, 20 event Timer, Install / Users Guide, 2 yr warranty
SAVE MORE $$$ USING "PAY-BY-CHECK" FAX-READY ORDER FORM
click link to see DISCOUNT order form & "PAY-BY-CHECK" prices
DID YOU KNOW WE ALSO OFFER MADE-TO-ORDER SYSTEMS WITH YOUR PREFERRED FITTINGS / CONNECTIONS
(Prefer straight fittings instead? Simply tell our associate when placing your order)
HEAD PRESSURE the pumps ability to "push" a 1" column of water "up" a pipe. This being said a TL4000 system would not be adequate to push water up to a third floor since it is rated to 16 feet of head. The TL5000 system would be the better fit.
SYSTEM TYPE and DESIGNATORS (OPEN & CLOSED LOOPED SYSTEMS)
Homes with NO DEDICATED hot water return line OPEN-LOOP systems use Cold Water line as return line
TL4000N Small - Med size home Flow 1-14 gpm / 16' head
TL5000N Large size home Flow 1-28 gpm / 30' head
INSTALL TYPE LOCATION
COMMON Pump UNDER SINK connect as follows:
E and F - hot supply and hot faucet (interchangeable / either one)
H and G - cold supply or cold faucet (interchangeable / either one)
ALTERNATE Pump AT WATER HEATER (SOLENOID and TEMP PROBE near sink)
Requires running 5 wires (2 = temp probe, 3 = solenoid 18 AWG) from control box to temperature probe and solenoid valve near sink.
In series connect (1) check valve, temperature probe and solenoid valve, install between hot and cold pipes near end of line.
Homes with DEDICATED hot water return line CLOSED-LOOP uses existing Hot Water return line
TL4000D Sm - Med size home Flow 1-14 gpm / 16' head
TL5000D Large size home Flow 1-28 gpm / 30' head
INSTALL TYPE LOCATION
COMMON Pump AT WATER HEATER drain spout (helps prevent sediment buildup at bottom of water heater)
Rotate pump head to achieve desired direction of flow into water heaters drain spout (tell us when placing order we'll do it for you, saving you time)
Connect flanges to hot water loop, include temperature probe. (Unless relocating to last load on loop. RECOMMENDED for efficiency)
ALTERNATE Pump ELSEWHERE ON LOOP (for efficiency install probe just after last hot water load)
EFFICIENCY-BASED ENGINEERING
Closed-Loop hot water circulation systems typically utilize a pump and thermostat installed at the end of the loop. Often resulting in needless energy consumption, additional demand on the water heater and longer then necessary pump operations. RedyTemp®'s unique design offers significant savings by strategically locating the stainless steel water contacting temperature probe near the last hot water load on the loop while still installing the pump at the water heater or other preferred location on the look. Thus, minimizing pump cycle runtimes and an overall much more efficient system by not heating piping past the last hot water load on the loop.
LIMITLESS PLUG-N-PLAY CONTROL

EXAMPLES OF WIRELESS "OUTLET" CONTROL DEVICES ON THE MARKET
EASILY SWAPPED-OUT INSTEAD OF USING TIMER (WIRELESS WALL SWITCH, VOICE, etc.)
RedyTemp is designed for quick and easy plug-n-play control customization. Most any outlet controlling device can be swapped out with the digital timer to achieve unique style of operation . The outlet control devices shown above are examples of the countless types on the market. These were all found on the internet, priced less than $20 each and typically available in big brand stores and home improvement centers.
ON-DEMAND OPERATION USING RJ11 PHONE JACK
The RJ11 phone jack "C" on the control box allows for on-demand / push-button "single cycle" operation. If used with a timer, push-button will act as an override adding additional convenience to a families lifestyle. Wiring additional rooms with push-buttons is simple using a 3 to 1 or larger phone adapter as indicated in the below illustration identified as components "F" and "G". Using any standard phone cord, simply cut one end off of the phone cord, strip the two middle wires and connect to any non-illuminating doorbell button or momentary contact switch. Plug the opposite end of the phone cord into the RJ11 jack. Anytime the button is pressed the system will run until the temperature setpoint is satisfied and then stop. The system will not run again unless either the timer schedules operation or the button is pressed again.
F = Multi-Phone Adapter; easy / cost efficient expansion of wired push-buttons
G = Standard Door Bell Button;
any momentary contact button or switch.
Note: RJ11 contacts
do not contain electricity, activation is by closing circuit /
momentary contact

SUPERIOR WIRELESS USES HOUSEHOLD ELECTRICAL WIRES TO TRANSMIT SIGNALS
FOR EASY MULTIPLE ACTIVATION POINTS FROM ANYWHERE IN HOME
For multiple wireless activation points throughout a home the homeowner would need to acquire the above X10 products of their choice. We do not stock these items but they are easy to find on the internet and affordable. Simply search the modules name and model number shown in the diagrams and listed below. "B" is a Transceiver Module it "transmits" on-commands by using the homes wiring system to cause Module "C" to momentarily cause the phone wires to make contact. Only one (1) module "C" is needed at the pumps location. The prongs on module "C" are on the back near the top and do not block usage of the second wall outlet. For multiple wireless activation points you need two components at each location.
Push-button operation requires one "E" and one "B" at each remote location
E = Wireless Remote
KR22A; Push-button wireless remote,
easily mounts using velcro strip or magnet.
B = Transceiver Module TM751;
Relay's on-command using the homes electrical wiring to activate "C".
Motion activated operation requires one "D" and one "B" at each remote location
D = Motion Sensor
MS16A; uses AAA batteries (battery life
1 year) place facing toilet / stall or other direction require a passing hand to
activate.
B = Transceiver Module TM751; Relay's on-command using the homes electrical wiring to activate "C".
In the above diagrams the user would push the button on "E" or activate motion sensor "D". The signal is received by "B" and transmitted to "C" through the homes existing electrical wires. Power line Command technology is not limited like most wireless devices which have limitations in range or obstructions, so you never experience problems of being too far away or line-of-sight issues experienced with other on-demand hot water circulators.
We do not stock or carry these items but are easily found all over the internet and on X10.com website. These plug-and-play (no programming required) wireless controls are favored by many RedyTemp owners.
BELOW ARE TYPICAL PRICES WE FOUND ON THE INTERNET FOR THESE ITEMS (we do not carry these items):
Module "B" = TM751 = $8.99
Module "E" WIRELESS REMOTE = KR22A = 5 FOR $19.99
(place multiple push-buttons or sensors throughout home, i.e. nightstand, kitchen, guest bath, etc.)
Module "C" = UM506 = $8.99
C = Universal Module UM506
Provides momentary contact to RJ11. Replacing timer for on-demand
only operations. Or, plug into wall socket leaving digital timer plugged
into control box provides wireless "single-cycle" scheduled-off override.
Timer-based hot water convenience remains set, very convenient for users with
flexible work schedules or who travel frequently.